Modular Data Center
A Modular Data Center system is a portable method of deploying data center capacity. A Modular Data Center can be placed anywhere data capacity is needed.
Modular Data Center system is study in modules to allow multiple power and cooling options. Modules can be shipped to be added, integrated or retrofitted in an existing data center or combined into a system of modules.
SAIVER Modular Data Center is custom designed to meet the project requirement. Each product is optimized for easy maintenance and a competitive price. Each unit is delivered in multiple modules for site assembly. Secondary modules can be deployed at later stage. SAIVER Modular Data Center are equipment for guarantee Tier level II or III.

MDC Brochure
Download
The Advantages
-
Low PUE – 1.04 to 1.10 depending on IT load
-
Quick deployment – Lead time 6 to 10 weeks depending on destination plus two days for installation and commissioning.
-
Easy maintenance
-
Modularity
-
Competitive price
-
Tier level II or III
Principles of Operation
- Uses fresh outdoor air – removes the need for mechanical cooling. Mechanical cooling only where air temperature and/or humidity is too high to be controlled by evaporative cooling
- Where temperature > maximum operating specification – uses the evaporative cooling effect of sprayed water
- In low temperature conditions – controlled by mixing the outside air with part of the returning air from the hot aisle
- In low humidity conditions – controlled by leveraging the humidity increase given by the evaporative cooler
- Fan speed and air flow – controlled by monitoring the inlet temperature and the IT power load
Models
1-4 RM-EDGE
? Delivered in single module
? Indoor or Outdoor installation
? Up to 4 racks 530mm wide four post fixed racks or roll in racks
? Up to 7kW/Rack density
? DX cooling with integrate DX condensing unit or Chilled Water Cooling Coil
? TIER II or TIER III
? PLC control with remote monitoring capability
? N+1 Fans

4 RM
? Delivered in multiple modules for site assembly. Secondary modules can be depoyed at later stage
? Indoor or Outdoor installation
? 4 racks per module maximum 16 racks
? 530mm wide four post fixed racks or roll in racks
? Up to 18kW/Rack density
? Optional DX or Chilled Water Cooling Coil
? TIER II or TIER III
? PLC control with remote monitoring capability
? N+1 Fans

10-20-40 RM
? Delivered in multiple modules for site assembly.
? Indoor or Outdoor installation
? Up to 20 racks 530mm wide four post fixed racks or roll in racks
? Up to 35kW/Rack density
? Optional DX or Chilled Water Cooling Coil
? TIER II or TIER III
? PLC control with remote monitoring capability
? N+1 Fans

30 RM
? Delivered in multiple modules for site assembly
.
? Indoor or Outdoor installation
? 30 racks 530mm wide four post fixed racks or roll in racks
? Up to 35kW/Rack density
? Optional DX or Chilled Water Cooling Coil
? TIER II or TIER III
? PLC control with remote monitoring capability
? N+1 Fans